Toshiba MR-3018 Scanner User Manual


 
MR-3018 Adjustment June 2005 © TOSHIBA TEC
5 - 10
Duplex copying:
(1) Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
Fig.5-21
(2) If the image skew is "C" as shown in the figure below, shift the aligning plate in the direction of "-
", and if "D", shift it to "+".
Fig.5-22 Fig.5-23
Shift the aligning plate in the direction of "-". Shift the aligning plate in the direction of "+".
C
D