Toshiba MR-3018 Scanner User Manual


 
MR-3018 Troubleshooting June 2005 © TOSHIBA TEC
6 - 2
6.2 Troubleshooting for Electrical Errors
1) RADF does not work (except in the case of a paper jam or when the cover is open)
2) Abnormality of motor
3) Communication error
4) Size detection error
Interface harness connected properly?
NO Connect the harness properly or replace it
YES
DC+5V supplied to CN70-2, 3pin?
NO Connect the harness properly or replace it
YES
DC+24V supplied to CN70-6, 7pin?
NO Connect the harness properly or replace it
YES
DC+24V supplied to CN72-4pin?
NO Check or replace the jam access cover switch
YES
Empty sensor is ON when there is paper?
NO Check or replace the empty sensor
YES
Check or replace the RADF board
Power supplied and drives signals to connector of motor?
NO Check or replace motor
YES
There is no mechanical overloading at the motor and the drive system is correct? (Belt tension etc.)
NO Check or replace motor harness
YES
Check or replace the RADF board
Interface cable normal?
NO Replace the interface cable
YES
Check or replace the RADF board and check the equipment
Original tray sensor is ON when there is paper?
NO Replace the sensor or harness
YES
Registration roller does not catch the original?
YES Clean the roller with alcohol or replace
NO
Original width detection sensor-1 is ON when there is paper?
NO Replace the sensor or harness
YES
Original width detection sensor-2 is ON when there is paper?
NO Replace the sensor or harness
YES
Check or replace the RADF board