Toshiba MR-3018 Scanner User Manual


 
MR-3018 DISASSEMBLY AND ASSEMBLY June 2005 © TOSHIBA TEC
4 - 20
(7) Remove 3 screws and then take off the
bracket.
Fig.4-54
(8) Take off 1 timing belt and 4 bushings.
Fig.4-55
(9) Loosen 1 screw of the belt tensioner.
(10) Remove the E-ring, and then take off the pul-
ley and timing belt.
Note: Note:
When the unit is being assembled, first install
the parts removed at steps (5), (6), (7) and
(9), and attach the spring removed at step (4)
next. Then tighten the screw loosened at
step (8).
Fig.4-56
Bracket
Screw
Timing belt
Bushing
Timing belt
Tensioner
E-ring
E-ring