Toshiba MR-3018 Scanner User Manual


 
June 2005 © TOSHIBA TEC MR-3018 DISASSEMBLY AND ASSEMBLY
4 - 25
4
[B] Gate solenoid (SOL2)
(1) Take off the original pickup solenoid.
( P.4-24 "[A] Original pickup solenoid
(SOL1)")
(2) Disconnect one connector. Remove 2
screws and take off the gate solenoid with
the bracket.
Fig.4-69
(3) Remove 2 screws and take off the gate sole-
noid from the bracket.
Fig.4-70
Note: Note:
When installing the gate solenoid, be sure to
align the edge of the bracket with the mark-
off line on the frame.
Fig.4-71
ScrewConnector
Screw
Gate solenoid
Gate solenoid
Mark-off line