Vixel 335 Switch User Manual


 
Vixel Model 335 Installation & Configuration Guide CHAPTER 3 Management
45
To enable or disable a policy:
1. Enter the number for the desired policy.
2. Enter 2 to enable the policy or 3 to disable the policy.
To view your changes, type mc and an updated list appears.
Threshold Information
Note: The Threshold
settings should not be
modified unless directed to
do so by Vixel Customer
Support.
An explanation of the threshold settings follows:
To set thresholds:
1. Enter the number for the desired threshold.
2. Enter a value for the threshold.
To view your changes, type mc and an updated list appears.
Settings Description
ASIC build number
Assigned number to the internal switch processor. Cannot be
modified or configured.
OS error threshold
Sets the number of Ordered Set errors that the switch will see on
a connection within the Error Count Threshold timeframe.
CRC error threshold
Sets the number of CRC errors the switch sees in frames within
the Error Count Threshold timeframe.
Switch stall threshold
Sets the number of microseconds until a stall is triggered.
Clk error thresh (ppm)
Sets the variance between the line-derived clock of fill words and
the switch internal clock.
Clk error prescale (1-
16)
Note: This setting should not be modified unless directed to do
so by Vixel Customer Support.
Err count thresh
(cSecs)
Sets the amount of time between error counter reads when
threshold errors occur.
Bad zone thresh
(cSecs)
Sets the amount of time that the zone can be down when the
switch thinks the zone should be operational.
Bad zone bypass
(cSecs)
Sets the amount of time the ports remain bypassed before
reinsertion.