Vixel 335 Switch User Manual


 
Vixel Model 335 Installation & Configuration Guide APPENDIX C Event Messages
64
132 Zone up then down The zone state has cycled
through the “up” and “down”
states several times. Current
zone state (at the time of this
message) is down.
--- Warning
133 Zone down then up The zone state has cycled
through the “up” and “down”
states several times. Current
zone state (at the time of this
message) is up.
--- Warning
140 Port inserted A port was inserted onto the
zone (after being bypassed).
--- Info
141 Port bypassed
(LIPF8)
A port was bypassed (could not
insert) because a LIP(F8) was
received at port input. (A
LIP(F8) indicates a loop fail-
ure.)
Check all connections
for the specified port.
Info
142 Port bypassed (tx
fault)
A port was bypassed because
the switch detected a transmit-
ter fault on the port’s trans-
ceiver.
Contact an authorized
service representative.
The transceiver may
need replacing.
Info
143 Port bypassed
(timeout)
A port was bypassed (could not
insert) because no LIP(F7)s
were received after continuous
transmission of LIP(F7)s for
112 milliseconds.
--- Info
145 Port bypassed A port was bypassed for a rea-
son other than transceiver
transmitter fault, invalid
response, or manual bypass.
--- Info
146 Port bypassed then
inserted
A port was bypassed, then
inserted.
--- Info
147 Port inserted then
bypassed
A port was inserted, then
bypassed.
--- Info
150 Transceiver inserted A transceiver was inserted. --- Notice
151 Transceiver removed A transceiver was removed. --- Notice
160 Management active Agent is operational. --- Info
165 Agent task asserted
on prev exec cycle
During normal operations, an
attempt to execute a command
was aborted due to an internal
error in the firmware.
The switch automatically resets
after the occurrence.
Contact an authorized
service
representative.
Critical
166 Agent machine
exception on prev
exec cycle
A task attempted to execute an
unknown command. The
switch automatically resets
after the occurrence.
Contact an authorized
service
representative.
Critical
170 Diagnostic function
aborted
A diagnostic setting is miscon-
figured and required a firm-
ware override.
Check diagnostic set-
tings for incompatibili-
ties.
Warning
200 CRC error detected CRC errors were detected in a
frame received on a port.
No action required. You
can modify the CRC
Error threshold through
the Web Manager or
CLI interface.
Info
201 CRC error threshold
exceeded
During the past ten seconds, the
number of CRC errors in
frames received by the specified
port exceeded the current
threshold value.
No action required. You
can modify the Error
Count threshold through
the Web Manager or
CLI interface.
Info
202 OS Error threshold
exceeded
During the past ten seconds, the
number of OS errors (invalid
transmit words, or 8b/10b
encoding errors) in frames
received by the specified port
exceeded the current threshold
value.
No action required. You
can modify the Error
Count threshold through
the Web Manager or
CLI interface.
Info
Ref
Event
Message
Meaning Action Severity