Vixel 335 Switch User Manual


 
Vixel Model 335 Installation & Configuration Guide APPENDIX C Event Messages
65
203 Port switch connect
overflow
A number of stalls have
occurred in a specific amount
of time.
--- Info
204 Port switch stall An instance occurred where
two devices could not discon-
nect communications with one
another.
--- Info
205 Port switch bad
open
A device is trying to send an
OPN but it cannot be delivered.
--- Info
206 Port clock delta freq
error
The switch clock or a device
clock are not synchronized. If
the switch clock has failed, the
error should display on multi-
ple ports. If only one port is
logging this error, it is most
likely a problem with that
device.
--- Info
207 Port clock delta freq
ok
The switch clock and a device
are synchronized.
--- Info
208 Bad zone detected Refers to the zone health. --- Info
209 Cascade user mode
overridden
A user setting for cascades has
been overridden by the firm-
ware.
--- Info
210 Console password
changed
The command line interface
password was changed. Note:
The password cannot be
changed without supplying the
current password, even if
logged on.
--- Notice
241 Port bypassed
(external loopback)
A port was bypassed manually,
through either the command
line interface or a management
entity.
--- Info
242 Port bypassed
(diagnostic TX)
A port was bypassed manually,
through either the command
line interface or a management
entity.
--- Info
243 Port bypassed (Loss
of RX signal)
Although a transceiver is
present, the port is bypassed
because there is no signal com-
ing into the port.
--- Info
244 Port bypassed (Loss
of Sync)
Although a transceiver is
present, the port is bypassed
because the port lost sync with
the fibre channel signal (no
command characters were
received).
--- Info
250 Port transmitter
enabled
A port transmitter was turned
on, through either the com-
mand line interface or a man-
agement entity.
--- Notice
251 Port transmitter
disabled
A port transmitter was turned
off, through either the com-
mand line interface or a man-
agement entity.
--- Notice
260 Key feature enabled A purchased license key for an
optional feature was entered,
through either the command
line interface or a management
entity.
--- Info
261 Key feature disabled An optional feature was dis-
abled, through either the com-
mand line interface or a
management entity.
--- Notice
270 Daytime server up The daytime server is running. --- Info
271 Daytime server
down
The daytime server is not run-
ning.
--- Notice
Ref
Event
Message
Meaning Action Severity