Zebra Technologies Z4Mplus Printer User Manual


 
14 Z4Mplus/Z6Mplus User Guide 13163L Rev. 3 5/20/2004
Printer Setup
Select a Communication Interface
Parallel Port Communicating using the parallel port (see Figure 8) does not require special
settings. The serial settings do not affect the parallel port. Refer to Parallel Data Port
on page 107
for further information.
Figure 8 • Communicating Using a Parallel Port
Cable Requirements
Data cables must be fully shielded and fitted with metal or metallized connector shells.
Shielded cables and connectors are required to prevent radiation and reception of electrical
noise.
To minimize electrical noise pickup in the cable:
Keep data cables as short as possible.
Do not bundle the data cables tightly with the power cords.
Do not tie the data cables to power wire conduits.
Printer
Computer
36-pin
male
25-pin
male
PC
25-pin
female
10 ft. (3 mm) maximum
Note • Zebra printers comply with FCC Rules and Regulations, Part 15 for Class B Equipment
using fully shielded, 6.5 ft (2 m) data cables. Use of unshielded cables may increase radiation
above the Class B limits.
Note • RS-422 and RS-485 applications should use twisted shielded pairs as recommended in
the TIA/EIA-485 Specification.