Downloading a Firmware Image
D-Series CLI Reference 2-35
3. Type 2.Thefollowingbaudrateselectionscreendisplays:
1 - 1200
2 - 2400
3 - 4800
4 - 9600
5 - 19200
6 - 38400
7 - 57600
8 - 115200
0 - no change
4. Type 8tosettheswitchbaudrateto115200.Thefollowingmessagedisplays:
Setting baud rate to 115200, you must change your terminal baud rate.
5. Settheterminalbaud rateto115200andpressENTER.
6. Fromthebootmenuoptionsscreen,type4toloadnewoperationalcodeusingXMODEM.
WhentheXMODEMtransferiscomplete,thefollowingmessageandheaderinformationwill
display:
[Boot Menu] 4
Ready to receive the file with XMODEM/CRC....
Ready to RECEIVE File xcode.bin in binary mode
Send several Control-X characters to cCKCKCKCKCKCKCK
XMODEM transfer complete, checking CRC....
Verified operational code CRC.
The following Enterasys Header is in the image:
MD5 Checksum....................fe967970996c4c8c43a10cd1cd7be99a
Boot File Identifier............0x0517
Header Version..................0x0100
Image Type......................0x82
Image Offset....................0x004d
Image length....................0x006053b3
Ident Strings Length............0x0028
Ident Strings...................
D2G124-12
Image Version Length............0x7
Image Version Bytes.............0x30 0x2e 0x35 0x2e 0x30 0x2e 0x34 (0.5.0.4)
7. Fromthebootmenuoptionsscreen,type2todisplaythebaudrateselectionscreenagain.
8. Type 4settheswitchbaudrateto9600.Thefollowingmessagedisplays:
Setting baud rate to 9600, you must change your terminal baud rate.
9. Settheterminalbaud rateto9600andpressENTER.
10. Fromthebootmenuoptionsscreen,type1tostartthenewoperationalcode.Thefollowing
messagedisplays:
Operational Code Date: Tue Jun 29 08:34:05 2004
Uncompressing.....