ADTRAN 25 Network Card User Manual


 
APPENDIX C: System Additions or Changes
Add Terminal
1.
2.
3.
4.
5.
6.
Evaluate the cabinet unit power load using the procedures under
“Evaluate cabinet unit Power Load” in this appendix.
Check for available ports on
checking the octopus cables
the back of the cabinet.
a compatible CP using the SAT or by
attached to the 25-pair receptacles on
the building wiring from the terminal toIf a port is available, connect
an unused termination on the SIP, following the instructions under
“connect Cabinets to SIP” in Section 2. Then, insert plug on the
octopus cable into the modular jack.
If a port is not available, add the correct CP and octopus cable,
following the procedures under
“Add Circuit Pack” in this appendix.
Then connect the building wiring from the terminal to a termination
on the SIP, following the procedures under “Install Cross-Connect
Equipment” in Section 2.
Next, connect the new CP to the SIP with
an octopus cable, following the procedures under “Connect Cabinets
to SIP” in Section 2.
Finally, install the terminal, following the
procedures under “Install Terminals” in Section 2.
Follow standard procedures for translating the terminal port using
the SAT.
Document the new terminal on the Voice and Data Station Records
Form.
C-10