ADTRAN 25 Network Card User Manual


 
APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
7047: incorrect PDC
Can verify that the PDC is not in a
not in any DGC group
DGC group by:
Go to MENU = 8 Search
ACTION = 1 DATA = 6
ACTION = 2 DATA = PDC
(hit c to continue)
7048: incorrect PDC
Do a Search to find the DGC group
not in this DGC group
the PDC is a member of.
Go to MENU = 8 Search
ACTION = 1 DATA = 6
ACTION = 2 DATA = PDC
(hit c to continue)
7049:
incorrect PDC
Incorrect virtual facility access code.
must enter pool member
7050:
action number out of
Must administer the access code
sequence
before administering the speed
must enter access code
dialing number.
Go to MENU = 4
System Administration
ACTION = 25 DATA = 100-189
ACTION = 26 DATA = Speed
Number [0-9, * , #]
Must administer the access code
before administering the virtual
facility number.
ACTION = 25 DATA = 190-199
ACTION = 26 DATA = VF number
[0-9
*, #]
7051: entry out of range
Access code must be 100-189 for
speed number must be
system speed dialing.
100-189
7052: incorrect entry
Speed number must be [0-9, *, #].
illegal character within
speed number
7053: entry out of range
Under Administering System-Wide
must be 0-1 for pooled
Options in the Admin. manual for
modem options
pooled modem options must be a
0-1
F-24