Basic Configuration
Page 3-42
Table 3-9 X/Y/Z Modem Image File Downloading settings
Performing a Software Upgrade
Use the following procedure to upgrade the IntraChassis 9000 software through
its serial (console) port.
1 In the Image File Download Configuration menu, type x to
open the X/Y/Z Modem Image File Downloading menu.
2 Type x, y, or z to select the corresponding modem protocol.
Note: For information about these protocols, see the
manual for your communications software.
3 Type c to select the console baud rate. The Baud Rate Set-
ting menu appears, as shown in Figure 3-25. The maximum
baud rate currently supported is 57,600 bps.
Setting Description
Bank 1 Image Version/
Date
The version number and compilation date of runtime code that is
stored in memory Bank 1 on the IntraChassis 9000.
Bank 2 Image Version/
Date
The version number and compilation date of runtime code that is
stored in memory Bank 2 on the IntraChassis 9000.The (Run-
ning) designation indicates that the runtime code is currently run-
ning on this Bank. The same as the image file in the boot bank.
Download Protocol Current setting of the IntraChassis 9000’s serial download proto-
col.
Current Baud Rate Transmission rate for the IntraChassis 9000’s serial port.
Destination Bank Number of the memory bank where the image file will download.