Astro Pneumatic 22834-464 Label Maker User Manual


 
QLS-4100 X 34
Press the SELECT key. The display will show the following prompt:
Press and hold the FORM FEED/ADVANCE key until the liner is inside the sensor
bracket. On notched media, temporarily slide the media out so that it is com-
pletely clear of the sensor assembly.
Press the SELECT key. The display will show the following prompt:
Press and hold the FORM FEED/ADVANCE key until the next label is inside the
Gap sensor.
Press the SELECT key. The display will show the following prompt:
Press and hold the FORM FEED/ADVANCE key until the next gap is positioned
behind the Media Sensor Assembly and in close proximity to the guide arrow
indicated on the center plate.
Press the SELECT key and observe the gap size on the display. The gap size
should be the same as the measured gap of your media and the following mes-
sage will be displayed:
6
7
8
9
10
11
12
Place Media @ Sensor
Then Press Select
Place Liner @ Sensor
Then Press Select
Place Gap @ Arrow
Then Press Select
Pause: Gap
Calibration OK