Baldor MN1851 Tablet User Manual


 
Receiving & Installation 3-5MN1851
Table 3-1 Wire Size and Protection Devices (for units with Power Supply)
Catalog Number Incoming Power
Input
Nominal Input
Continuous Input
Input
Fuse
Wire Gauge
Nominal Input
Voltage
Output
Amps
(RMS)
Breaker
(A)
Time
Delay (A)
AWG
(USA)
mm
2
(Europe)
LP1A02SR-EXXX
115V (1f)
2.0A 8 8 14 2.5
LP2A02SR-EXXX
230V (3f)
2.5A 10 10 14 2.5
LP1A02TR-EXXX
115V (1f)
2.0A 8 8 14 2.5
LP2A02TR-EXXX
230V (1f)
2.5A 10 10 14 2.5
LP4A02TB-EXXX
400/460V (3f)
2.5A 10 10 14 2.5
LP1A05SR-EXXX
115V (1f)
5A 20 20 14 2.5
LP1A05SR-EXXX
230V (3f)
5A 20 20 14 2.5
LP1A05TR-EXXX
115V (1f)
5A 20 20 14 2.5
LP2A05TR-EXXX
230V (1f)
5A 20 20 14 2.5
LP4A05TB-EXXX
400/460V (3f)
5A 20 20 14 2.5
LP1A07TR-EXXX
115V (1f)
7.5A 30 30 14 2.5
LP2A07TR-EXXX
230V (1f)
7.5A 30 30 14 2.5
LP4A07TR-EXXX
400/460V (3f)
7.5A 30 30 14 2.5
LP1A10SR-EXXX
115V (1f)
10A 40 40 14 2.5
LP2A10SR-EXXX
230V (3f)
10A 40 40 14 2.5
LP1A15SR-EXXX
115V (1f)
15A 60 60 12 2.5
LP2A15SR-EXXX
230V (3f)
15A 60 60 12 2.5
LP4A15TR-EXXX
400/460V (3f)
15A 60 60 12 2.5
LP4A20TR-EXXX
400/460V (3f)
20A 60 60 12 2.5
Table 3-2 Wire Size (for units without Power Supply)
Catalog Number
Continuous
Wire Gauge
Bus
Voltage
Continuous
Output
Amps
AWG
(USA)
mm
2
(Europe)
LP1A02PO-EXXX 160VDC 2.0A 14 2.5
LP2A02PO-EXXX 300VDC 2.5A 14 2.5
LP1A05PO-EXXX 160VDC 5.0A 14 2.5
LP2A05PO-EXXX 300VDC 5.0A 14 2.5
LP1A10PO-EXXX 160VDC 10.0A 12 2.5
LP2A10PO-EXXX 300VDC 10.0A 12 2.5
LP1A15PO-EXXX 160VDC 15.0A 10 2.5
LP2A15PO-EXXX 300VDC 15.0A 10 2.5
Note: All wire sizes are based on 75°C copper wire. Higher temperature smaller gauge wire may
be used per NEC and local codes. Recommended fuses/breakers are based on 25°C
ambient, maximum continuous control output current and no harmonic current.
X1 Power Connections
Power connections are shown in Figures 3-5 through 3-8.