Baldor MN1851 Tablet User Manual


 
Specifications & Product Data 7-5MN1851
Encoder Input (Feedback)
Description Unit All
Signal Type RS422
Operating Mode A / B Quadrature
Maximum Input Frequency kHz 400
Cycle Time msec 1
Serial Interface (Option LPxAXXXXXX2X)
Description Unit All
Communication Type RS232C (not galvanically isolated)
Transmission Rate Baud 9600 (not adjustable)
Optional Interface (Option LPxAXXXXXX4X)
Communication Type RS485 (not galvanically isolated)
Transmission Rate Baud 9600 (not adjustable)
Regeneration (115 / 230VAC)
Description Unit LPx
A02T
LPx
A05T
LPx
A07T
LPx
A02S
LPx
A05S
LPx
A10S
LPx
A15S
Switching Threshold
115VAC
230VAC
VDC
ON: OFF:
188 - 195 183 - 188
373 - 383 362 - 372
ON: OFF:
180 200
388 375
Nominal / Peak Power (10% Duty Cycle) kW 0.25 / 2.7
Maximum Regeneration Switching Current A 10
Maximum Load Inductance
mH
100
Regeneration (400 / 460VAC)
Description Unit LP4 A02 LP4 A05 LP4 A07 LP4 A15 LP4 A20
Switching Threshold 400/460VAC VDC ON: 794 OFF: 764
Nominal / Peak Power (10% Duty Cycle) kW 0.94 / 9.4 2.9 / 29
Maximum Regeneration Switching Current A 15 45
Maximum Load Inductance
mH
100