Baldor MN1851 Tablet User Manual


 
B-6 Command Set MN1851
PLC Parameters:
Command Description Units Range Default E
2
/ Par. set
PLC.LINE Defines PLC statement :IF [input]=TRUE,
THEN [action] set/started, with syntax
PLC.LINE [num] [action] [input] [num]
[action] PLC line number, and string
parameter for PLC action, fixed to line
number:
num: 0 : 12
action: s. left
lines:
input: s. left
lines:
PLC disabled,
all lines:
input = false
E / P
0 ENABLE (PLC enable)
1 MAO1 (Digital Input MAO1)
2 MAO2 (Digital Input MAO2)
3 MAO3 (Digital Input MAO3, if available)
4 MAO4 (Digital Input MAO4, if available)
5 RELAY (
6 USRERR (Error 9)
7 FRST (Fault Reset)
8 DISA (Disable active, s. 0)
9 DISP (Disable active, s. 0)
10 HOLD (Holdstatus, s. 0)
11 JOG (JOG function, s. 0)
12 GEAR
[input] string parameter with enumerated
values:
FALSE: Always false, i.e. switched off
CW, CCW: Hardware or Software
Limit Switches
MAI1, MAI2 : Digital Inputs
MAI3, MAI4: Digital Inputs (if
available)
DRVOT,MTROT: Drive respectively
motor overtemperature
I2tWRN: I
2
Twarning (error 7)
TRUE: Always true, i.e. switched ON
INPOS, FEWRN, FEFAT: Flags of
Position Controller in position,
following error warning, following error
limit (s. 0)
BADMOV: Not initialized motion buffer
line commanded (s. 0)
MOTRDY, MOTNRDY: Positioning
finished respectively in process
Note: Choice of Inputs and Outputs is not completely available in all configurations
Variables: NONE
PLC Methods:
Command Description Parameter Units Range
PLC Enables (on) / disables (off) / clears and disables (clr)
PLC. PLC on and off command is stored in PLC buffer line
0.
on, (off), clr