Brother BE-1204C-BC All in One Printer User Manual


 
11-4 BE-1204B-BC • BE-1206B-BC
Chapter 11 Error code list
Code Error Measures
E-36 Needle overhang (-X, +Y)
E-38 Needle overhang (-Y)
E-39 Needle overhang (+X, -Y)
E-3C Needle overhang (-X, -Y)
Pattern or the needle position is out of the embroidering area.
Reset the embroidering area on the panel or move the hoop to
the sewable position.
E-40
The status of presser foot is issued as an alarm
when every second machine is used.
E-41 Invalid start-up error
This is not usually displayed.
E-42 XY movement error
Press the
or turn on the F/B switch on the head to either
side. If this error occurs frequently, check if the tension of the
pulley belt is proper.
E-43 I/F CPU failed to read EEPROM data
Turn the power off and on once. If the same error occurs
again, the main PC is faulty.
E-44
Failed in the communication with inter-head
CPU
Press the
or turn ON the F/B switch on the head to either
side. If the same error occurs again, the connector of
communication cable on the inter-head CPU may be
disconnected.
E-45 Failed in the communication with head CPU
Press the
or turn ON the F/B switch on the head to either
side. If the same error occurs again, the connector of
communication cable on the head CPU may be disconnected.
E-46 Failed in the communication with XY CPU
Press the
or turn ON the F/B switch on the head to either
side. If the same error occurs again, the main PCB is faulty.
E-47 Failed in the communication with I/F CPU
Press the
or turn ON the F/B switch on the head to either
side. If the same error occurs again, the main PCB is faulty.
E-48 The main shaft rotated the opposite way
Turn OFF the power and check if the sensors of the encoder A
and B are connected correctly, not mixed-up each other. If
those connections are correct, then check if the pin connections
of the main shaft motor connectors are correct.
E-49 Can not identify the machine model
Turn OFF the power, check if the model identification harness is
connected properly, and turn ON the power again.
E-4A Failed in the communication with I/O CPU
Press the
or turn ON the F/B switch on the head to either
side. If the same error occurs again, the connector of
communication cable on the I/O PCB may be disconnected.
E-A1 Spindle motor lock
Press the
or turn on the F/B switch on the head to either
side. If it occurs frequently, the main shaft mechanism is
faulty.
E-A2 Main PC board temperature too high
E-A3 Spindle motor voltage too low
E-A4 Spindle motor voltage too high
E-A5 Spindle motor CPU error
E-A6
Spindle motor CPU communication command
error
E-A7 Spindle motor CPU send/receive error
This is not usually displayed.
E-A8 Spindle stop position signal error
Adjust the pulley stop position (100 °) above the needle and
press the
. If the error occurs frequently, the parts related
to the main shaft stop position sensor are faulty.
E-A9 Spindle CPU parameter error
E-B0 Lower shaft CPU error
E-B1 Thread tangle in rotary hook
This is not displayed in this model.