Canon X600 Projector User Manual


 
User Command Specifications
9Details of command GET ERR
1
GET ERR
GET ERR
GETER
R
?ER
R
g
:ERR=<Erro
r
ID:ID>
NO_ERROR No error
ABNORMAL_TEMPERATUR Temperature error
FAULTY_LAMP Lamp error
FAULTY_LAMP_COVER Lamp cover error
FAULTY_COOLING_FAN Cooling fan error
FAULTY_POWER_SUPPLY Power supply error
FAULTY_AK AK error
FAULTY_ASC ASC error
FAULTY_AF AF error
FAULTY_POWER_ZOOM Zoom error
FAULTY_POWER_FOCUS Focus error
For all other responses, refer to "Error List."
-1 This inquiry can be executed in any status provided that AC power is supplied to the projector.
-2
"NO_ERROR" is returned when the warning LED is not lighted.
> GET ERR or ? ERR
< g:ERR=FAULTY_LAMP
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
s
OFF ON PM
○○○
○○○
* If a command cannot be supported, 'INVALID_MODE' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
X600
Information when the warning LED of the projector is flashing can be obtained.
SX50 SX6 SX60
01.00** 01.01** 01.01**
○○
Commands
Function
Format
Error information inquir
y
Mode Control Setting
Description
Response
This inquires about the current error information.
ID
Error ID
Reference
01.01**
Model Power
Input
D-RGB A-RGB1 A-RGB2 Comp Video
Mode
Remote Local
Remarks
S-Video D-Video SCART None
SX50
○○○○○○––○○×
SX6
○○○ ○○○○○○○
SX60
X600
Command
s
supported
Example
For the "SX50," the remote mode must be established.
○○
○○
○○
Errors supported by model
SX50 SX6 SX60 X600
○○
○○
○○
○○○
○○○
○○○
Meaning
○○
○○
○○
○○
PAGE 122