User Command Specifications 9. Details of command PROG
2
PROG
PROG
PROG=<Progressive conversion setting parameter
s
:ID>
Progressive conversion setting parameters
This command is used to set the progressive conversion processing to ON or OFF.
-1
A "busy" response is given while the zoom or focus lens is being driven.
Furthermore, it may not be possible to execute the command with some input signals.
-2
Menu
[Image adjustments] - [Progressive]
[Display settings] - [Progressive]
-3
-4 The menu display statuses are as listed in the table below by model.
Menu display statuses, etc.
・1080i ・720p ・480p ・1035i ・575p
・1080i ・720p ・480p ・1035i ・575p
(Reference)
・1080i
・720p ・480p
・1035i
・575p
-5
Significance of acquired valu
e
Setting currently established for progressive conversion
Setting
> PROG=0 This sets the progressive conversion setting to OFF.
< i:OK
Reference
>
GET PROG or ?PROG
< g:PROG=1
Acquisition of parameters which can be set
> RANGE PROG
< r:PROG=I, 0, 1, 2
* Commands are indicated by ">", and responses are indicated by "<".
"0," "1" or "2" can be selected as the progressive
conversion setting.
When signals from a progressive source have been input, the progressive
conversion setting can be selected, but the field will be blank on the menu.
If the input signals are "Component" signals of any of the following types, the
signals cannot be processed even when "ON" or "AUTO" has been selected as the
progressive conversion setting to perform progressive conversion, but the value on
the menu will change. However, the value will be grayed out.
The current value can be acquired using the applicable GET command. The significance of the
acquired values is given in the table below.
For details, refer to the GET command.
SX60
SX6
SX50
Current progressive conversion processing status (1: conversion underway, 0:
no conversion)
○○
0 OFF
○○
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
For details, refer to the RANGE command.
○○
1ON
○○
2
○
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
Format
Errors supported by model
X600
○
AUTO
Description
Response "i:OK" is returned if the parameter was set properly.
Parameter
SX6
SX60
X600
Example
SX6
SX50
×
X600
ID
SX60
○
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
Parameter Meaning
SX50
Commands
Function Progressive setting
Mode Control Setting Reference
This command is the same as the menu functions in the table below.
This sets the currently selected input signal and image mode.
Model
Model
SX50
X600
Model
SX60
SX6
If the input signals are "Component" signals of any of the following types, the
signals cannot be processed even when "ON" has been selected as the
progressive conversion setting to perform progressive conversion.
With the SX50, IP_NOT_AVAILABLE is returned for both
referencing and setting in response to the signals on the left.
This acquires the progressive conversion processing
status.
PAGE 34