Cisco Systems ME3400G2CSA Switch User Manual


 
36-17
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
78-17058-01
Chapter 36 Troubleshooting
Using TDR
To end a trace in progress, enter the escape sequence (Ctrl-^ X by default). Simultaneously press and
release the Ctrl, Shift, and 6 keys, and then press the X key.
Using TDR
These sections contain this information:
Understanding TDR, page 36-17
Running TDR and Displaying the Results, page 36-17
Understanding TDR
You can use the Time Domain Reflector (TDR) feature to diagnose and resolve cabling problems. When
running TDR, a local device sends a signal through a cable and compares the reflected signal to the initial
signal.
TDR is supported only on the copper Ethernet 10/100 ports on the Cisco ME switch.
TDR can detect these cabling problems:
Open, broken, or cut twisted-pair wires—The wires are not connected to the wires from the remote
device.
Shorted twisted-pair wires—The wires are touching each other or the wires from the remote device.
For example, a shorted twisted pair can occur if one wire of the twisted pair is soldered to the other
wire.
If one of the twisted-pair wires is open, TDR can find the length at which the wire is open.
Use TDR to diagnose and resolve cabling problems in these situations:
Replacing a switch
Setting up a wiring closet
Troubleshooting a connection between two devices when a link cannot be established or when it is
not operating properly
Running TDR and Displaying the Results
To run TDR, enter the test cable-diagnostics tdr interface interface-id privileged EXEC command:
To display the results, enter the show cable-diagnostics tdr interface interface-id privileged EXEC
command. For a description of the fields in the display, see the command reference for this release.
Note TDR is supported only on the copper Ethernet 10/100 ports on the Cisco ME switch.