Cisco Systems SCE 2000 4xGBE Network Router User Manual


 
Chapter 8 Troubleshooting
Troubleshooting Overview
SCE 2000 4xGBE Installation and Configuration Guide
8-4 OL-7824-02
ip address: 10.1.6.145
subnet mask: 255.255.0.0
Configured duplex: auto
AutoNegotiation is On, link is Up, actual duplex: half
show interface GigabitEthernet 0/# counters: Displays the values of counters of a
GBE interface.
Following is a sample output from the show interface counters command.
In total octets: 191520
In good unicast packets: 560
In good multicast packets: 0
In good broadcast packets: 0
In packets discarded: 0
In packets with CRC/Alignment error: 0
In undersized packets: 0
In oversized packets: 0
Out total octets: 0
Out unicast packets: 0
Out non unicast packets: 0
Out packets discarded: 0
Refer to The User Log (on page 8-4) for an explanation of commands related to the user log.
The User Log
The user log is an ASCII file that can be viewed in any editor. It contains a record of system
events, including startup, shutdown and errors. You can use the Logger to view the user log to
determine whether or not the system is functioning properly, as well as for technical support
purposes.
The Logging System
Events are logged to one of two log files. After a file reaches maximum capacity, the events
logged in that file are then temporarily archived. New events are then automatically logged to the
alternate log file. When the second log file reaches maximum capacity, the system then reverts to
logging events to the first log file, thus overwriting the temporarily archived information stored in
that file.
Basic operations include:
Copying the User Log to an external source
Viewing the User Log
Clearing the User Log
Viewing/clearing the User Log counters