Cisco Systems SCE 2000 4xGBE Network Router User Manual


 
Chapter 8 Troubleshooting
Troubleshooting Overview
SCE 2000 4xGBE Installation and Configuration Guide
8-8 OL-7824-02
SCE 2000 Operational Status
The following table lists the operational states of the SCE 2000. The Status LED on the SCE
2000 Front Panel reflects the current SCE 2000 operational status. The operational status can be
displayed using CLI command show system operation-status.
Table 8-2 SCE 2000 Operational States
SCE 2000
Operational
Status
Description Status LED State
Booting Initial state after reset Orange
Operational SCE 2000 becomes operational after completing the following
process:
Boot is completed
Power self-tests are completed without failure
Platform configuration is applied
Flashing green
Warning SCE 2000 is fully operational (as above) but one of the
following occurred:
Line ports (GBE ports) to the link are down
Management port link is down
Temperature raised above threshold
Voltage not in required range
Fans problem
Power supply problem
Insufficient space on the disk
Note: If the condition that caused the SCE 2000 to be in
Warning state is resolved (for example, link is up) the SCE
2000 reverts to Operational state.
Flashing orange
Failure System is in Failure state after Boot due to one of the following
conditions:
Power on test failure.
Three abnormal reboots in less than 20 minutes
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command).
Note: Depending on the cause of failure, the management
interface and the platform configuration may or may not be
active/available.
Red