Cisco Systems SCE 2000 4xGBE Network Router User Manual


 
Chapter 8 Troubleshooting
Problem Solving Using a Subsystems Approach
SCE 2000 4xGBE Installation and Configuration Guide
8-12 OL-7824-02
Troubleshooting the Management Subsystem
Check the following to help isolate a problem in the management subsystem.
Problems in the management subsystem could be any of the following:
Management link is down. (Mng LINK LED not lit--also Status is WARNING)
Management link is up (Mng LINK LED lit) but does not answer ping
Telnet connection cannot be established due to link problems (Mng LINK LED not lit)
Management link is up (Mng LINK LED lit) but Telnet connection cannot be established
Telnet connection established, but terminates automatically
Note
When the management link is down and/or a Telnet connection cannot be established, you must open a
CLI session on a local terminal connected to the CON port. This enables you to solve the problem and
then reconnect through the management port.
Table 8-6 Troubleshooting the Management Subsystem
Symptom Diagnostic Action Possible Cause Possible Solution
Management link down:
Mng LINK LED not
lit
Status is WARNING
(Status LED is
flashing orange)
CLI command
show interface
FastEthernet 0/0
ping to
management
interface fails
RJ 45 connector is not
connected to the platform or
to the network
Reconnect the cable to the Mng
1 port and to network.
Cable is connected to Mng 2
port.
Reconnect the cable to the Mng
1 port.
Cable is broken Check / Replace the cable.
Management link up:
Mng LINK LED is lit
ping to
management interface
fails
CLI commands
show ip route
show ip default-
gateway
One of the following
configurations may be wrong:
IP address / subnet mask
IP default gateway
See Initial System Configuration
(on page 5-3)
Refer to "IP Configuration" in
the Cisco SCE 2000 4xGBE
Software Configuration Guide.
CLI command
show access-lists
An ACL may be assigned
that denies entry.
See Initial System Configuration
(on page 5-3)
Refer to "Access Control Lists"
in the Cisco SCE 2000 4xGBE
Software Configuration Guide.
Telnet connection
cannot be established
Mng LINK LED is
not lit (link is down)
CLI command
show interface
FastEthernet 0/0
Management interface IP
address or subnet mask is
incorrect
Check / reconfigure
management port IP address and