Dell C4130 Server User Manual


 
Physical
Height 4.31 cm (1.7 inch)
Width 43.4 cm (17.09 inch)
Length 88.58 cm (34.87 inch)
Maximum configuration weight 20.2 kg (44.53 lb)
Empty weight 12 kg (26.45 lb)
Environmental specifications
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950
m or 3117 ft)
10°C to 25°C (50°F to 77°F) with no direct sunlight
on the equipment.
NOTE: Certain system configurations may
require reductions in the upper temperature
limits.
NOTE: The performance of the system may
be impacted when operating above the
upper temperature limit or with a faulty fan.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Relative humidity
Storage 5% to 95% RH with 33°C (91°F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Operating 10% to 80% relative humidity with 21°C (69°F)
maximum dew point.
Maximum vibration
Operating 0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations).
Storage 1.88 G
rms
at 10 Hz to 500 Hz for 15 min (all six
sides tested).
Maximum shock
Operating Six consecutively executed shock pulses in the
positive and negative x, y, and z axes of 40 G for
up to 2.3 ms.
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
175