CHECKING BASIC SYSTEM SETTINGS
Navigate through the controller menus and sub-menus to check system settings. You
can adjust any parameter as required. Note that these settings can also be checked (and
changed if required) via the WEB Interface.
Note: Repeatedly press the “ESC” key to return in reverse order level by level from any
sub-menu until the Main screen appears.
Procedure
To Select a Sub-Menu:
Press the up or down arrow keys to move the cursor up and down the list of sub-menus
in the menu screen (selects the sub-menu), then press ENT to enter the selected sub-
menu.
To Enter a Password:
If a password screen opens, a password must be entered to allow the User to make
adjustments. To enter a password, with the cursor at the User Name field (default is
“Admin”), press the down arrow key to move cursor down to the password line. Press
ENT. “0” is highlighted. Press the up arrow key once to change the “0” to”1” (default
password is “1”), then press ENT twice. (Note: If you have been assigned a unique
User Name and password, follow this procedure to enter these.)
To Change a Parameter:
Press the up or down arrow keys to move the cursor up and down the list of parameters
in the menu screen (selects the parameter to change), then press ENT to change the
selected parameter. The parameter field highlights. Press the up or down arrow keys to
change the parameter value. Press ENT to confirm the change.
Table 5-1 shows the menu navigation for some basic settings. (Refer to the ACU+
Controller Operation Instructions (UM1M820NNB-1) for details and additional settings.)