CHAPTER 14 Troubleshooting
Other Error Messages
An abnormality of the system monitoring feature itself as well as abnormality of main cabinet are
indicated by error messages on the LCD panel.
Table 14.7 Other Error Messages
Message level Message content Description
(1st line) (2nd line)
SCF: idling... nnn min, POWER nnn minutes passed after the power was turned on
after restoring the power.
RCI Mainte Mode RCI mode has changed for maintenance
I/O Power on The power-on sequence for peripheral units is
continuing.
SCF: warning Please Levelup Firmware upgrade processing is incomplete.
Re-executing upgrade processing is required.
SCF: alarm RCI Timeout Communication processor time-out detected.
FMEM Protected Flush Memory is write-protected
Syshalt nnnnnnnn Halt on main cabinet detected.
SCF: stop BUSerr nnnnnnnn Halt due to bus error. Automatically reset. If the
message is still displayed, however, the system
monitoring feature is down.
Error Message Abnormality is detected within the system monitoring
mechanism. If the message is still displayed,
however, the system monitoring feature is down and
power-on is disabled.
SCF Watchdog Hang-up due to watchdog detection. Automatically
reset. If the message is still displayed, however,
the system monitoring feature is down.