Chapter 3. Upgrading the Enterprise Virtual Array to v3.020
Figure 3.4. Command View EVA—Disk Enclosure
Properties page—checking the firmware version
e.
In the EMU group, record the number listed in the Firmware version field.
f. Repeat step d and step e for each disk enclosure in the rack. If there is more than
one rack in the storage system, record the firmware version for each disk enclosure
in the storage system.
4. Verify that there are no hardware components in the Unmappable Hardware folder.
a. Expand the navigation tree under the Hardware folder in the Navigation pane.
b. Click the Unmappable Hardware folder.
Hardware components can be placed in the Unmappable Hardware folder for several
reasons. For example, hardware components can be placed in the Unmappable
Hardware folder, when the I/O modules on a disk enclosure are not working,
the controllers restart, or there is a hardware failure. If there are any hardware
components listed under this folder, determine why they are listed there and fix the
problems.
5. Using Command View EVA, examine the controller event log. Verify that no Critical
events occurred in the last 48 hours.
a. Click a storage system icon in the Navigation pane.
b.
Click View Events.
The View Events page displays.
34
hp Stor ageWorks Enterprise Virtual Array Updating Product
Software Instructions