Chapter 3. Upgrading the Enterprise Virtual Array to v3.020
Caution
You cannot load code onto the controllers if:
The storage configuration is being changed in any way.
Wait until all c
onfiguration changes are completed in the Command View
EVA before proc
eeding with a code load.
In a Continuous Ac cess EVA configuration, a DR group is logging,
merging, leveling, or copying. Furthermore, none of the DR groups can
be in a failsafe locked state.
Click the DR group icon in the Navigation pane. Check the Log State
in the DR Group Properties page.
In a Continuous Access EVA configuration, the connection between the
storage systems is compromised or failed.
Click the Data Replication folder in the Navigation pane. Check the
Connection
State in the Data Replication Folder Properties page.
In Continuous Access EVA configurations, all EVA storage systems must be
running normally with fully functional controller pairs.
If you atte
mpttoloadcodeontothecontrollersbeforetheaboveconditions
are met, controller operation will fail.
In a Continuous Access configuration, after you load code onto the first
controller pair (for example, the source controller pair), you must wait at
least three minutes, or until the preceding conditions a re met on the sec ond
controll
er pair.
6.
Click Code load.
A confirmation message displays.
Figure 3.44. Command View EVA—first code load confirmation message
7.
Click OK.
The Code Load Storage System-Page 1 displays.
76
hp Stor ageWorks Enterprise Virtual Array Updating Product
Software Instructions