Chapter 3. Upgrading the Enterprise Virtual Array to v3.020
Installation is complete.
Installing hp StorageWorks SMI-S for EVA <Date> <Time>
Install Complete
Note
In some cases, the message, Rebooting this Appliance,displays.
If the installation fails for any reason, the Storage Management Appliance does not permit
a subsequent installation attempt for one hour following the failed attempt. Attempting an
installation during this one hour period displays an error message.
12.
Click Finish.
13. Verify that an SMI-S EVA entry is displayed on the Manage Tools page, in the Storage
Management Appliance software.
To view the Manage Tools page, click Settings on the Storage Management Appliance
home page, and then click Manage Tools.
If an SMI-S EVA entry is displayed, the installation is complete.
If the entry is not displayed, then go to step 8 to repeat the installation procedure.
Installing from a local disk on the Storage Management Appliance
To install SMI-S EVA v3.2 software on the Storage Management Appliance, complete the
following procedure:
1. Copy the installation file hpSMISEVA_3_2.swp to a shared network drive that is
accessible from the Storage Management Appliance.
2. Open a Microsoft Terminal Services session to connect and log on to the Storage
Management Appliance. If Terminal Services is not available, connect a monitor, mouse,
and keyboard to the Storage Management Appliance.
3. Connect from the Storage Management Appliance to the shared network drive that
contains the file, hpSMISEVA_3_2.swp.
4. Copy hpSMISEVA_3_2.swp from the shared network drive into the following directory
on the Storage Management Appliance:
C:\COMPAQ\SWPInstallKits
5. Disconnect from the shared network drive and log off Terminal Services.
6. Disconnect the monitor, keyboard, and mouse.
7. From a client computer, launch a Web browser and browse to the SMA, using the
following format:
http://<managementappliance_name>
hp StorageWorks Enterprise Virtual Array Updating Product
Software Instructions