Chapter 3. Upgrading the Enterprise Virtual Array to v3.020
Step 8: Upgradi
ng the VCS/Storage System Software to v3.020
Estimated Time to Complete
45 minutes
Before you can perform an online upgrade of the storage system software to v3.020 (which
includes VCS v3.020), you must be running VCS v3.010 (or later) on the HSV controllers. If
you need assistance in upgrading to VCS v2.00x or v3.010, please contact an HP Authorized
Service Representative.
Table 3.4 describes the proper upgrade paths to VCS v3.020.
Table 3.4. VCS/Storage System Software Upgrade Paths
Current VCS/
Storage System
Software Version
Upgrade Path
1.021
If you are running v1.021, you must
upgrade to a later version. Please contact
an HP Authorized Service Representative
to assist you .
2.000
1. Upgrade to v2.006.
ab
2. Upgrade to v3.01x
c
.
3. Upgrade to v3.020.
2.002
1. Upgrade to v2.006
b
.
2. Upgrade to v3.01x
c
.
3. Upgrade to v3.020.
2.003
2.004
2.005
1. Upgrade to v2.006
b
.
2. Upgrade to v3.01x
c
.
3. Upgrade to v3.020.
2.006
1. Upgrade to v3.01x
c
.
2. Upgrade to v3.020.
3.000
3.001
1. Upgrade to v3.01x
c
.
d
2. Upgrade to v3.020.
3.010
3.014
Upgrade to v3.020
abcd
a
If you have a Windows 2000 host, you must perform an offline upgrade to upgrade the storage system software from v2.000 to v2.003.
b
You can upgrade to v2.003, v2.004, v2.005, or v2.006, depending on your EVA type (refer to Table 2.2).
c
When you are running VCS v3.010, do not delete any LUNs, snapshots, or snapclones that exceed 1984GB.
d
If you are not using Continuous Access EVA in your storage solution, you can upgrade directly from VCS v3.000 or VCS v3.001 to
VCS v3.020.
The following procedure describes an online upgrade or rolling of the storage system software.
HP recommends that you perform an online or rolling upgrade when you upgrade from one
storage system software version to the next.
During an online upgrade of the storage system software, VCS is upgraded on the HSV
controllers, while they are still receiving I/O from the applications on the host servers. The
HSV controllers do reboot at the same time (usually within host OS timeout periods). Online
upgrades should be conducted at off peak hours. Furthermore, database applications with
access to the storage system should not be running.