HP (Hewlett-Packard) CF083A#201 All in One Printer User Manual


 
Formatter to control panel communication interruptions
The firmware does not fully initialize and configure the control panel interface.
The control panel is not functioning (either a failed component or power problem).
Interface cabling between the formatter and control panel is damaged or disconnected.
TIP: If the heartbeat LED is illuminated—by an error condition or normal operation—the formatter is
fully seated and the power is on. The pins for the LED circuit in the formatter connector are recessed so
that this LED will not illuminate unless the formatter is fully seated.
The heartbeat LED operates according to the product state. When the product is initializing, see
Heartbeat LED, product initialization on page 247. When the product is in Ready mode, see
Connectivity LED, product operating on page 249.
Heartbeat LED, product initialization
The following table describes the heartbeat LED operation while the product is executing the firmware
boot process.
NOTE: When the initialization process completes the heartbeat LED should be illuminated solid green
—the LED is off if the product is in Sleep mode.
If after initialization the heartbeat LED is not solid green, see
Connectivity LED, product operating
on page 249.
Table 3-2 Heartbeat LED, product initialization
Product initializing
state
Heartbeat LED, normal state Heartbeat LED, error state
No power (power cord
unplugged or power
switch off)
Off Not applicable
Power on (immediately
after the power switch
pressed)
Red, solid
Duration should be 1 second or less
Red, solid
Firmware error; problem finding hardware
and booting the serial peripheral interface
flash memory
Boot process halted
Replace the formatter.
Serial peripheral
interface (SPI) flash
memory boot
Green, solid Red, solid
Firmware error; problem corrupt or missing
SPI flash memory
Boot process halted
Replace the formatter.
ENWW
Tools for troubleshooting
247