Environmental requirements
To ensure proper o peration, the switch must not be subjected to environmental conditions
beyond those
for which it was tested. The ranges specified in Table 25 list the acceptable
environment
for both operating and non-operating conditions.
Table 25 Environmental requirements
Condition Acceptable
range during operation
Acceptable
range during
non-operation
Ambient
temperature
0° to 40° Celsius (32° to 104°
Fahrenheit)
-25°to70°Celsius(-13°to158°
Fahrenheit)
Humidity 10% to 85% RH non-condensing, at
40°Celsius(104°Fahrenheit),with
maximum gradient of 10% per hour
10% to 90% RH non-condensing, at
70°Celsius(158°Fahrenheit)
Altitude
3,000meters(9,842feet)abovesea
level
0 to 12 kilometers (39,370 feet) above
sea level
Shock
20 G, 6 ms
duration, half-sine wave
Half sin
e, 33G 11ms, 3/eg Axis
Vibration 0.5 G sine, 0.4 grms random, 5-500 Hz 2.0 G sine, 1.1 grms random 5-500
Hz
Airflow for 4/3 2
SAN Switch
24 cubic ft/minute
None required
Airflow for 4/8,
4/16, and 4/64
SAN Switches
47 cubic ft/minute
None r
equired
Airflow for 4/32B
SAN Switch
High speed, 9300 RPM,
20.8 cubic feet/ minute
Lowspeed,7200RPM,15.4cubicfeet/
minute
None required
NOTE:
The –10 ºC to +40 ºC range applies to the ambient air temperature at the air intake
vents on the nonport side of the switch. The temperature inside the switch can be up to
75 ºC during switch operation.
If the internal temperature range exceeds the operating ranges of the components,
the LEDs, error messages, and Fabric Watch alerts will indicate a problem. Issue the
tempshow command to view temperature status.
136