IBM AA-RWF3A-TE Switch User Manual


 
Table184/32SANSwitchPowerSupplyStatusLEDs
LED color
Meaning Corrective ac tion
No light The power supply i
snotreceiving
power or is off.
Verify that the power supply is on and seated
and that the power cord is connected to a
functioning power source.
Steady green Power supply is operating
normally.
No action required.
Steady amber
for more than 5
seconds
Power supply fault for one of the
following reasons:
Power cable is disconnected.
Power supply is off.
Power supply has failed.
Try the following:
Check the power cable connection.
Verify that the power supply is powered on.
Replace the power supply.
Items required
Replacing a 4/32 SAN Switch power supply should take less than two minutes and
requires the following items:
New power supply
Phillips #1 screwdriver
SAN Switch installation guide