IBM XSERIES 220 Computer Hardware User Manual


 
Symptom-to-FRU index 115
Diagnostic error codes
Note: In the following error codes, if XXX is 000, 195, or 197do not replace a FRU.
The description for these error codes are:
000 The test passed.
195 The Esc key was pressed to abort the test.
197 This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom FRU/Action
001-XXX-000 (Failed
core tests)
1. System Board
001-XXX-001 (Failed core
tests)
1. System Board
001-250-000 (Failed
System Board ECC)
1. System Board
001-250-001 (Failed
System Board ECC)
1. System Board
005-XXX-000 (Failed
Video test)
1. Video Adapter (if installed)
2. System Board
011-XXX-000 (Failed
COM1 Serial Port test)
1. System Board
011-XXX-001
(Failed COM2 Serial Port test)
1. System Board
014-XXX-000
(Failed Parallel Port test)
1. System Board
015-XXX-001
(USB interface not found,
board damaged)
1. System Board
015-XXX-015
(Failed USB External
Loopback test)
1. Make sure parallel port is not disabled
2. Re-run USB External Loopback test
3. System Board
015-XXX-198
(USB device connected
during USB test)
1. Remove USB devices from USB1 and USB2
2. Re-run test
3. System Board
020-XXX-000 (Failed
PCI Interface test)
1. System Board
030-XXX-000 (Failed
Internal SCSI interface test)
1. System Board
030-XXX-00N (Failed
SCSI test on PCI slot N.
Check system error log before
replacing a FRU.)
1. Adapter in Slot N
035-XXX-099 1. No adapters were found.
2. If adapter is installed re-check connection.