IBM XSERIES 220 Computer Hardware User Manual


 
122 Hardware Maintenance Manual: xSeries 220
962
(Parallel port error)
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. System Board
11XX
(System board serial port 1 or
2 error)
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. System Board
1162
(Serial port configuration
conflict)
1. Disconnect external cable on serial port
2. Run Configuration/Setup
3. System board
1200 (microprocessor
machine check)
1. Microprocessor
1800
(No more hardware interrupt
available for PCI adapter)
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1962
(Drive does not contain a
valid boot sector)
1. Verify a bootable operating system is installed.
2. If RAID system, refer to the Hardware Maintenance Manual for the specific RAID
adapter.
3. Run Diagnostics
4. Hard Disk Drive
5. Cable
6. SCSI Backplane
7. System Board
2400
(Video controller test failure)
1. Video Adapter (if installed)
2. System Board
2462 (Video memory
configuration error)
1. Video Adapter (if installed)
2. System Board
5962
(IDE CD-ROM configuration
error)
1. Run Configuration/Setup
2. CD-ROM Drive
3. CD-ROM Power Cable
4. IDE Cable
5. System Board
6. Battery
8603
(Pointing Device Error)
1. Pointing Device
2. System Board
00012000 (Processor machine
check)
1. Update BIOS
2. Replace microprocessor
00019501 (Microprocessor 1
is not functioning - check
VRM and processor LEDs)
1. Microprocessor 1
2. System Board
00019502 (Microprocessor 2
is not functioning - check
VRM and processor LEDs)
1. Microprocessor 2
2. System Board
Error Code/Symptom FRU/Action