IBM XSERIES 220 Computer Hardware User Manual


 
24 Hardware Maintenance Manual: xSeries 220
Duplicate slot numbers
detected.
Explanation: An attempt has been made to bind the same
slot number more than once.
Action: Check the slot numbers entered during the bind.
Adapter slot numbers must be valid and unique. If the
problem persists, contact your network supplier.
Xxx’ is not supported for
AFT team.
Explanation: A bind command has been issued for adapters
not supported by AFT.NLM.
Action: Make sure that you attempt to bind only adapters
supported by AFT.NLM.
Primary and Secondary
adapters do not match. AFT
group is not created.
Explanation: A bind command was entered for an adapter
team that is a combination of server and client adapters. An
AFT team must be a grouping of the same classification of
adapter.
Action: Verify that all the adapters bound in a team are of the
same classification.
Requested number of
Secondary cards are not
found.
Explanation: The number of adapters specified in the bind
command could not be located.
Action: Verify the numbers and slot locations of the adapters
to be bound. If the problem persists, contact your network
supplier.
Failed to create AFT group.
Make sure that the drivers
for supported adapters are
loaded, primary adapter is
bound to protocols, and
secondary adapter is not
bound to any protocols.
Explanation: Binding of protocol failed. Protocol is either not
bound to any adapter or is bound to more than one adapter in
the group.
Action: Ensure that the protocol is bound to only adapter in
an AFT team.
Error identifying slot
numbers for the specified
board names.
Explanation: The mapping between the board name entered
and the slot number for an adapter could not be established.
Action: Check the board name for the adapter before issuing
the bind command. If the problem persists, contact your
network supplier.
Can’t unbind specified slot
from AFT group. Make sure
that the slot you specified is
for the primary adapter in an
AFT group.
Explanation: The number entered in the unbind command
was not the primary adapter in an AFT group.
Action: Reissue the unbind command and specify the slot
number for the primary adapter.
LAN adapter at slot nnnn
(Port 0xaa) failed to reset.
Check the state of the
adapter.
Explanation: The adapter that you specified could not be
initialized.
Action:
1. Load the driver for the supported adapter.
2. Check that the adapter is seated properly in the slot and
try loading the AFT module again.
If the problem persists, contact your network supplier.
AFT is not supported on this
version of NetWare™.
Explanation: The NetWare on your server is not a version
supported by AFT.
Action: Load and bind AFT only on supported versions of
NetWare (currently version 4.11 and above).
Message Description