IBM XSERIES 220 Computer Hardware User Manual


 
116 Hardware Maintenance Manual: xSeries 220
035-XXX-S99 (Failed
RAID test on PCI slot S. S =
number of failing PCI slot.
Check System Error Log
before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN (Check
System Error Log before
replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99 (RAID
adapter initialization failure)
1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2. Cable
3. Adapter
075-XXX-000 (Failed
Power Supply test)
1. Power Supply
089-XXX-001 (Failed
Microprocessor test)
1. Microprocessor
089-XXX-002
(Failed Optional
Microprocessor test)
1. Optional Microprocessor 2
180-XXX-003 (Failed
System Board LED test)
1. System Board
201-XXX-0NN (Failed
Memory test, see "Memory
Settings" on page 32.) NN =
DIMM location.
1. DIMM Location J1-J4
2. Memory card
201-XXX-999 (Multiple
DIMM failure, see error text.)
1. See error text for failing DIMMs
202-XXX-001 (Failed
System Cache test)
1. Microprocessor CPU 1
202-XXX-002 (Failed
System Cache test)
1. Microprocessor CPU 2
206-XXX-000 (Failed
Diskette Drive test)
1. Cable
2. Diskette Drive
3. System Board
215-XXX-000 (Failed
IDE CD-ROM test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
217-XXX-000 (Failed
BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
1. Fixed Disk 1
Error Code/Symptom FRU/Action