Intel SE7320SP2 Computer Hardware User Manual


 
Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS Platform Management
Revision 2.0
107
voltage conditions, fan failures, etc. The management controller also provides the interface to
the sensors and SEL so System Management Software can poll and retrieve the present status
of the platform. The contents of the log can be retrieved ‘post mortem’ in order provide failure
analysis information to field service personnel. It is also accessible by System Management
Software, such as Intel Server Management (ISM), running under the OS.
The management controller includes the ability to generate a selectable action, such as a
system power-off or reset, when a match occurs to one of a configurable set of events. This
capability is called Platform Event Filtering, or PEF.
The management controller includes ‘recovery control’ functions that allow local or remote
software to request actions such as power on/off, power cycle, and system hard resets, plus an
IPMI Watchdog Timer that can be used by BIOS and run-time management software as a way
to detect software hangs.
The management controller provides ‘out-of-band’ remote management interfaces providing
access to the platform health, event log, and recovery control features via LAN (all tiers).
Standard and Advanced systems also allow access via serial/modem, IPMB, PCI SMBus, and
ICMB interfaces. These interfaces remain active on standby power, providing a mechanism
where the SEL, SDR, and recovery control features can be accessed even when the system is
powered down.
Because the management controller operates independently from the main processor(s), the
management controller monitoring and logging functions, and the out-of-band interfaces can
remain operative even under failure conditions that cause the main processors, OS, or local
system software to stop.
The management controller also provides the interface to the non-volatile ‘Sensor Data Record
(SDR) Repository’. IPMI Sensor Data Records provide a set of information that system
management software can use to automatically configure itself for the number and type of IPMI
sensors (e.g. temperature sensors, voltage sensors, etc.) in the system. This information allows
management software to automatically adapt itself to the particular system, enabling the
development of management software that can work on multiple platforms without requiring the
software to be modified.
The following are the common features supported by the mBMC.
Power System
System Reset Control
System Initialization
Watchdog Timer
System Event Log
Sensor Data Record (SDR) Repository
Field Replaceable Unit (FRU) Inventory Device
NMI Generation
SMI Generation
Self test
Secure mode
Boot options