Readable Value / Offsets
- Readable Value indicates the type of value returned for threshold and other non-
discrete type sensors.
- Readable Offsets indicates the offsets for discrete sensors that are readable via the
Get Sensor Reading command. Unless otherwise indicated, all Event Triggers are
readable, i.e., Readable Offsets consists of the reading type offsets that do not
generate events.
Event Data
This is the data that is included in an event message generated by the associated
sensor. For threshold-based sensors, the following abbreviations are used:
- R: Reading value
- T: Threshold value
The following table lists the core sensors located within the mBMC. These sensors are fixed and
hard-coded. They cannot be modified by a user.
Table 55: mBMC Built-in Sensors
Sensor Name Sensor # Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value /
Offsets
EventData
Physical
Security
Violation
01
Physical
Security
05h
Sensor
Specific
6Fh
LAN Leash
Lost
As
LAN Leash
Lost
Trig Offset
Platform
Security
Violation
02
Platform
Security
Violation
Attempt
06h
Sensor
Specific
6Fh
Out-of-band
access
password
violation
As – Trig Offset
Power Unit
Status
03
Power Unit
09h
Sensor
Specific
6Fh
Power On/Off
Power cycle
AC Lost
As – Trig Offset
Button 04h
Button
14h
Sensor
Specific
6Fh
Power Button
Reset Button
As – Trig Offset
Watchdog 05h
Watchdog2
23h
Sensor
Specific
6Fh
Timer Expired
Hard Reset
Power Down
Power cycle
Timer Interrupt
As – Trig Offset