Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS Platform Management
Revision 2.0
130
Sensor Name
Sensor
#
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value/Offsets
Event Data
PEF
Action
SDR
Record
Type
Tach Fan 3
(Front 3)
19h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 4
(Front 4)
1Ah
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 5
(Rear 1)
1Bh
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 6
(Rear 2)
1Ch
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc1 IERR 1Dh
Processor
07h
Sensor
Specific
6Fh
IERR As – Trig Offset – 02
Proc2 IERR 1Eh
Processor
07h
Sensor
Specific
6Fh
IERR As – Trig Offset – 02
Proc1 Thermal
trip
1Fh
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As – Trig Offset
Fault
LED
Action
02
Proc2 Thermal
trip
20h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As – Trig Offset
Fault
LED
Action
02
Proc1 Throttle 21h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog Trig Offset
Fault
LED
Action
01
Proc2 Throttle 22h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog Trig Offset
Fault
LED
Action
01
Diagnostic
Interrupt Button
23h
Critical
Interrupt
13h
Sensor
Specific
6Fh
FP NMI
Button
As – Trig Offset
NMI
Pulse
02
Chassis Identify
Button
24h
Button
14h
Generic
03h
Sate
Deasserted
State Assert
As – Trig Offset
ID LED
Action
02
Proc1 Fan 25h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc2 Fan 26h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc1 Core
temp
27h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc2 Core
temp
28h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
CPU
Configuration
Error
29h
Processor
07h
Generic
03h
State
Asserted
As & De Discrete R, T
Fault
LED
Action
02