Table 50. mBMC Factory Default Event Filters
Event Filter # Offset Mask Events
1 Non-critical Voltage Assert
2 Non-critical Voltage Deassert
3 Critical Voltage Assert
4 Critical Voltage Deassert
5 Critical PS Soft Fail Assert
6 Critical PS Soft Fail Deassert
7 Critical Proc 1-2 Thermal Trip Assert
8 Critical Proc 1-2 Thermal Trip, Config Error & IERR Deassert
9 Degraded Proc 1-2 FRB3 Assert
10 Degraded Proc 1-2 FRB3 Deassert
11 Degraded Proc 1-2 Hot Assert
12 Degraded Proc 1-2 Hot Deassert
13 Critical FP NMI Assert
14 Critical FP NMI Deassert
15 Non Critical SCSI Terminator Fail Assert
16 Non Critical SCSI Terminator Fail Deassert
17 N/A ID Button Assert
18 N/A ID Button Deassert
19 Critical Fan Speed Assert
20 Critical Fan Speed Deassert
21 Non Critical Fan Speed Assert
22 Non Critical Fan Speed Deassert
23 Critical Temperature Assert
24 Critical Temperature Deassert
25 Non Critical Temperature Assert
26 Non Critical Temperature Deassert
27 Critical Proc 1-2 IERR Assert
28 Critical CPU Configuration Error
29 N/A Reserved for ISM
30 N/A Reserved for ISM
5.2.12.2 Alert over LAN
LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps to a specified alert
destination. The Alert over LAN feature is used to send either Platform Event Trap alerts or
directed events to a remote system management application, regardless of the state of the
host’s operating system. LAN alerts may be sent over the LAN channel specified for the
platform. LAN alerts can be used by PEF to send out alerts to selected destination when ever
an event matches an event filter table entry For more information on LAN alerts, see the IPMI
Specification v1.5.