Kodak 20R Printer User Manual


 
Diagnostics and Troubleshooting
September 2000 5-17
202 The following parameter is
invalid:_parametername:
_parametervalue_.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
203 The function is not supported
by the class.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
204 This function has not been
implemented.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
205 Must enter the following
field:_field_.
The operator left a blank
configuration field.
Enter information in the blank
configuration field.
301 The following key was not
found _key_.
An internal error occurred with
the software.
One of the files was edited
manually and a key was
changed.
Restart the application.
Restore the key to its previous
value.
If problem continues, call for
service.
302 The following grouper was
not found:_grouper_.
An internal error occurred with
the software.
One of the files was edited
manually and a grouper was
changed.
Restart the application.
Restore the grouper to its
previous value.
If problem continues, call for
service.
303 The call depends on a
current grouper, but the
current grouper has not been
set.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
501 An error occurred while
applying the data.
601 A bad count was entered.
The expected count
was:_count_.
A file was edited manually and
an incorrect number of rows
was entered.
An internal software error
occurred.
Manually enter the correct
number of rows in the file.
If problem continues, call for
service.
602 An error occurred during the
calculation process.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
701 Patch _patch_, column
_column_, value _value_ is
beyond tolerance
_tolerance_ for aim _aim_.
A density patch was out of
tolerance.
Perform another calibration cycle.
702 Patch _patch_ has a spread
of _spread_ which is out of
range _range_.
The spread between colors for a
given density patch is out of
tolerance.
Perform another calibration cycle.
703 CalToleranceFile can only be
initialized once.
An internal error occurred with the
software.
Restart the application.
If problem continues, call for
service.
Error
Code
Error Code /Status
Message
Possible Cause/Subsystem Possible Solution