Lucent Technologies 555-232-102 Webcam User Manual


 
Procedure: WT Firmware Download and Connection
Issue 5 June 1999
4-13
0x82 Low WT timed out waiting for the program data from
the RC.
For the 9601 WT, restart the download process.
For the 9630 Series WT, the download
automatically restarts; therefore, no user
intervention is required.
0x83 High Download cable is not connected.
Connect the download cable between the RC
and the WT, and restart the download process. If
the cable is connected and the error continues to
occur, use another download cable.
0x84 High Error while programming flash device.
Restart the download process. If the error
continues to occur, try a fully charged battery.
0x85XX High Flash memory erase error; reason XX.
Restart the download process. If the error
continues to occur, try a fully charged battery.
0x86 Low WT timed out waiting for RC “info” message.
For the 9601 WT, restart the download process.
For the 9630 Series WT, the download
automatically restarts; therefore, no user
intervention is required.
0x87 High RC wants to communicate at a bad baud rate.
Restart the download process.
0x88 High RC wants to send a file in an unsupported
format.
Restart the download process.
0x891 High The connected RC circuit pack is not enabled or
assigned as a server and is therefore disabled
from allowing WT upgrades.
Check the Feature-Related System Parameters
form at the bottom of page 2 for the RC circuit
pack. If the circuit pack is not listed, issue the
change system feature command and add it to
the list. Then issue the enable wt-upgrade
[
PPCSS
] command.
Table 4-2. WT Download Error Codes (continued)
Error Code Severity Description/Recommendation