Switch Administration
2-12 Issue 5 June 1999
22. If the DWBS has 9630 Series WTs, administer them.
Native support is not provided for the 9630 Series WT. Except for the
physical handset, the 9630 Series WT is identical to the 9601 and 9601+
WTs. The 9630 Series WT is administered as an alias of either the 9601
WT or 9601+ WT via the Alias Station form.
Whenever you want two call appearances, you should administer the 9630
Series WT to a 9601 WT. Whenever you want three call appearances, you
should administer the 9630 Series WT to a 9601+ WT.
To access the Alias Station form, enter the change alias station
command. An example of the form appears as follows.
Table 2-1. Radio Controller Circuit Pack Form Fields
Field Name Explanation
RC Location
This field displays the cabinet, carrier, and slot of the TN789 circuit
pack. No input is required.
WFB A Parameters
Location
Enter the code for WFB A followed by a description of its physical
location (for example, “3A-1st floor aisle”). The code for WFB A is
provided on the floor plan.
This field must be administered if the internal antenna or at least
one CAU on the WFB is administered as y.
Internal Antenna
Enter n, unless you have an internal antenna via a special order
from Lucent Technologies.
CAU Conn
Enter y to designate that a particular CAU is connected to the
WFB. The default is n.
NOTE: Once the CAU is administered and attached, be sure to
busy out and release the WFB.
Location
Enter a description of the physical location of the connected CAU
(for example, “front aisle/hardware”).
This field must be administered if the associated
CAU Conn
field is
set to y.
WFB B Parameters
NOTE: Repeat the previous process for WFB B, if applicable.