Lucent Technologies 555-232-102 Webcam User Manual


 
DWBS Testing
4-2 Issue 5 June 1999
1. Contact the Initialization and Administration System (INADS) center for the
appropriate firmware download.
2. Perform a firmware upgrade for the appropriate component(s) by following
the directions in the next section (for the WT) or in the DWBS Maintenance
document (for the other DWBS components).
Procedure: WT Firmware Download
and Connection
The firmware for the 9601 or 9630 Series WT is updated via the download cable
connected to the TN789 RC circuit pack that is administered as a download
server. For the 9601 WT, a 9600 baud RS232 connection is used; for the 9630
Series WT, a 38400 baud RS232 connection is used. The download cable must
be within 50 feet of the RC circuit pack. For longer distances, range-extension
devices are required.
Determining if a Firmware Download is
Required
The following procedure is required for all new, existing, or replacement WTs.
1. From the DEFINITY ECS management terminal (MT), enter the status
wt-upgrade command (for firmware that is stored in the RC). This
command brings up the Status of Wireless Terminal Firmware Upgrade
form. An example of the form appears as follows: