Cell Antenna Unit
Issue 5 June 1999
3-37
Figure 3-19. 559C Outdoor CAU
To install a 559B or 559C Outdoor CAU, do the following:
!
WARNING:
The installation of outdoor CAUs for the DWBS must conform to the local
electrical code for grounding.
1. Mount the outdoor CAU in the location specified by the installation map.
Specifically, do the following:
NOTE:
Ensure that you mount the CAU
vertically
.
a. Verify that there is a flat, structurally sound mounting surface at the
specified location. If such a surface is not available, the customer
must provide one.
b. Using the mounting template shown in the following figure, drill
appropriate holes for 1/4 in. screws. Pan head sheet metal screws
with dimensions 1/4 in. by 1 1/4 in. are included with the unit.
Masonry anchors or other mounting hardware must be provided
locally.