2-13
Figure 2-9. Alias Station Form
The
Alias Set Type
field in the form represents the aliased set type, and it
can contain a maximum of seven characters. The associated
Supported
Set Type
field is a keyword field that accepts a value for any natively
supported set type. Therefore, for example, if you want three call
appearances, enter 9630 into the
Alias Set Type
field and 9601+ into the
Supported Set Type
field. On the other hand, if you want two call
appearances, enter 9630 into the
Alias Set Type
field and 9601 into the
Supported Set Type
field.
Once the 9630 Series WT is aliased, it is subject to all of the restrictions,
including feature capabilities, of its associated supported set type. Aliasing
is transparent to the end user.
Once you submit the form, the value that you entered into the
Alias Set
Type
field (for example, 9630) appears as a valid value in the
Type
field in
the Station form (whenever this form is accessed via the add station
command). Also, the appropriate form is displayed whenever value 9630 is
entered into the
Type
field in the Station form.
All other commands that accept a set type as a valid option (for example,
list station type
9630
) also accept value 9630 as if it were natively
supported in the DEFINITY ECS.
Page 1 of 1
ALIAS STATION
change alias station
Alias Set Type
9630
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
Supported Set Type
9601+
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
‘#’ indicates previously aliased set type is now native