A
Product Manager Messages
A-21
Product Manager Messages
Action Review the Switch Binding Membership List to determine if the
devices should be members.
Message Port diagnostics cannot be performed on an inactive port.
Description This displays when port diagnostics is run on a port in an inactive
state.
Action Run the diagnostics on an active port.
Message Port speeds cannot be configured at a higher rate than the
director/switch speed.
Description This displays when you configure a port to 2 GB/sec and the switch
speed is set to 1 Gb/sec.
Action Set the port speed to 1 Gb/sec in the Configure Ports dialog box.
Message Product Manager error <number>.
Description The switch Product Manager encountered an internal error and
cannot continue.
Action Report the problem to support personnel.
Message Product Manager instance is currently open.
Description A Product Manager window is currently open.
Action Informational message only.
R
Message R_A_TOV must be greater than E_D_TOV.
Description R_A_TOV must be greater than E_D_TOV.
Action Change one of the values so that R_A_TOV is greater than E_D_TOV.