2
Hardware View
2-11
Monitoring and Managing the Switch
— 07 Non-McDATA switch at other end of the ISL. The cable is
connected to a non-McDATA switch and interop mode is set to
McDATA fabric mode.
— 08 ISL connection not allowed on this port. The port type
configuration does not match the actual port use (the port is
configured as an F_Port, but attaches to a switch or director).
— 10 Port binding violation - unauthorized WWN. The WWN
entered to configure port binding is not valid or a nickname
was used that is not configured through the Product Manager
for the attached device.
— 11 Unresponsive node connected to port. Possible causes are:
• Hardware problem on switch or on a connected node
where ELP frames are not delivered, the response is not
received, or a fabric login in (FLOGI) cannot be received.
There may be problems in switch SBAR.
• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out FLOGI
within reasonable time frame.
Segmented E_Port Messages:
— Incompatible operating parameters, such as resource
allocation time-out values (R_A_TOV) or error-detect time-out
values (E_D_TOV) are inconsistent. Refer to Configure Switch
Parameters on page 3-3 for more information.
— Duplicate domain IDs. Refer to Configure Switch Parameters on
page 3-3 for more information.
— Incompatible zoning configurations. Refer to sections on
joining zoned fabrics in the Sphereon 4500 Fabric Switch
Installation and Service Manual (620-000159) and the Enterprise
Fabric Connectivity User Manual (620-005001) for details.
— Build fabric protocol error.
— No principal switch (no switch in fabric is capable of being
principal switch).
— No response from an attached switch.