Mocomtech CRS-300 Switch User Manual


 
CRS-300 1:10 Redundancy Switch Revision 16
Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM
5–7
Furthermore, in Ethernet Bridge Mode, the parameter backup mechanism is unsupported;
therefore, the User must make sure that all parameters match in the Online and Offline modems.
Refer to the SLM-5650 or SLM-5650A Installation and Operation Manual for detailed
configuration information.
5.2.4.4.3 Ethernet Bridge Mode Configuration via Optional GbE Interface
Due to backplane limitations, the CRS-300 can support Single-port Ethernet Bridge Mode only.
Ethernet Bridge Mode redundancy, when using SLM-5650/5650 modems equipped with the
optional 10/100/1000 Base-T (GbE) Interface, is provided by a Single IP Address scheme.
To configure the SLM-5650/5650A for Ethernet Bridge Mode 1:1 redundancy, for each modem
enter a unique IP Address for the optional 10/100/1000 Base-T (GbE) Interface card that is on the
same subnet:
CONFIG Æ MODE Æ INTERFACE Æ GIGABIT ETHERNET
Refer to the SLM-5650 or SLM-5650A Installation and Operation Manual for detailed
configuration information.